THE ONLY SOURCE FOR PROFESSIONAL ICI ROOFING CONTRACTORS IN ONTARIO ORN 16 ONTARIO ROOFING NEWS – ISSUE 3 2026 Blue Roofs performance during the 2021 grow- ing season at the George Vari Engi- neering and Computing Centre at the Toronto Metropolitan Univer- sity. The roof was comprised of a 50-mm compost layer, a 250-mm substrate, a filter sheet, a 50-mm drainage layer, a root barrier and a roofing membrane arranged from top to bottom. The membrane and drain system were not mentioned in the study. The research highlighted the roof’s water retention capabil- ity, with average rates between 85 and 88 per cent and peak stormwater attenuation of 82 to 85 per cent.19 Temperature-wise, the study ob- served a mean air temperature reduc- tion of 1.4°C to 2.5°C, varying with the type of vegetation.19 Notably, the cooling effects were more significant in the afternoon and evening, while a warming trend was noted in the early morning.19 While prototypes exist for tray systems, check-dammed systems and blue-green roofs, limited research and case studies exist for RID sys- tems, flagging a potential area for further research and development. This gap in research limits practitio- ners’ understanding of RID systems and their performance across various membrane types. Relevant Canadian Codes and Standards While specific standards for blue roofs have yet to be established within Canadian building codes and standards, the principles for gen- eral roof design remain pertinent. This section examines how existing roofing codes and standards can be adapted to blue roof applications, ensuring their functional and struc- tural integrity. The 2020 National Plumbing Code (NPC) contains provisions for roof drainage relevant to blue roofs. Section 2.4.10.4(1) determines the maximum hydraulic load used to es- tablish the minimum leader size for the roof drain. For roof drains with flow controls, the hydraulic load is determined using a 25-year rainfall intensity-duration-frequency curve provided by Environment Canada.20 NPC clauses 2.4.10.4(2) and (3) stipulate that water stored on the roof should not remain for more than 24 hours and have a maximum depth of 150 mm (six in.).20 Ad- ditional clauses in the NBC 2015 specify the location of drains, which must be no more than 15 m (49 ft.) from the edge of the roof and no more than 30 m (98 ft.) from adja- cent drains.20 Additionally, overflow scuppers must be installed no more than 30 m (98 ft.) apart along the perimeter of the building to prevent structural overloading of the roof if drains fail.20 However, the NPC does not mandate specific roofing membranes. Many regionally specific codes, such as the 2012 Ontario Building Code (OBC), share requirements comparable to those of the NPC drainage guidance. The distinction lies in the sourcing of environmen- tal data, where references in the OBC must adhere to the Ministry of Municipal Affairs and Housing (MMAH) Supplementary Standard SB-1 instead of NPC data.21 Different municipalities and re- gions may also have specific storm- water management and retention requirements. For example, the To- ronto Green Standard (TGS) Ver- sion 4 applies to new site plan ap- plications for four-storey or higher residential buildings and all indus- trial, commercial and institutional (ICI) developments.22 Within the water quality and efficiency pre- requisite WQ1.1, Water Balance, Quality & Quantity Control, there is a mandate to retain 50 per cent of the total average annual rainfall volume, remove 80 per cent of to- tal suspended solids and control E. coli for discharges to Lake Ontario or waterfront sites.22 Peak flow con- trol is also required; however, chal- lenges arise in implementing blue roofs under prerequisite WQ1.3, On-site Green Infrastructure, due to conflicting requirements, such as minimum vegetative roof coverage, which can be up to 80 per cent of available roof space.22 These require- ments pose challenges in blue roof implementation, with the standard specifications supporting vegetative roof infrastructure. Designers may consider implementing blue roofs in the remaining available roof space or installing a hybrid blue-green roof to meet the Toronto bylaw re- quirements. The City of Toronto also has a Wet Weather Flow Master Plan, which sets wet-weather flow- management targets for water bal- ance, quality and quantity. Table 1 in Section 2.2.1, Water Balance, lists examples of on-site stormwater man- agement practices depending on the type of land use.23 For example, com- mercial and industrial buildings may implement vegetative roofs, rooftop restrictors and rainwater harvesting. CSA A123.26:21, Performance Requirements for Climate Resilience of Low Slope Membrane Roofing Sys- tems, lists even more stringent rec- ommendations related to drainage. The standard outlines the require- ments for low-sloped membrane roofing systems to achieve different ratings related to climate adaptation. According to Clause 7.2.8, water should not run more than 10.7 m (35 ft.) to a primary drain or scup- per to achieve a silver performance rating.24 For a gold performance rating, Clause 7.2.13 stipulates that water should not travel more than 6.1 m (20 ft.) to a primary drain or scupper.24 CSA 478:19, Durability in Buildings, provides minimum re- quirements to assist designers in making design decisions, review- ing construction and performing building maintenance in existing and new construction projects.25 Blue roofs can influence the lifes- pan and performance of a building due to their unique construction and environment. For example, Sections 4.3 and 4.4 of this stan- dard state that all foreseeable agents and mechanisms that could impact durability and performance must be considered and accounted for during design, construction, re- pair and maintenance.25 Similarly, Section 8.3, Clauses (b) and (c), specify that the materials selected must be appropriate for the struc- ture’s environment, design loads and differential movements.25 Sec- tion 4.6.2 stipulates that a mainte- nance and inspection plan should be developed for building compo- nents, including repair and replace- ment.25 This makes proper mate- rial selection for the waterproofing membrane and a thorough mainte- nance and repair plan essential for blue roofs. Leak detection is an important consideration for blue roof systems. It can provide quality assurance during construction and a mean of leak diagnostics and monitoring for the lifecycle of the roof assembly. In considering leak detection during design, the following standards of- fer guidelines and requirements for electronic-detection components: ASTM D7877, Standard Guide for Electronic Methods for Detecting and Locating Leaks in Waterproof Membranes, and ASTM D823, Standard Practice for the Use of a Low Voltage Electronic Scanning System for Detecting and Locating Breaches in Roofing and Water- proofing Membranes.26,27 Lastly, CSA B805:22/ICC 805:22, Rainwater Harvesting Systems, provides comprehensive guidelines for the design, materials, installation and operation of rain- water harvesting systems, covering potable and non-potable applica- tions and water treatment.28 It can apply to blue roofs if detained water is reused within the building for po- table or non-potable uses. Case Study Building Description The Credit Valley Conserva- tion (CVC) Head Office, located at 1255 Old Derry Road in Mississauga, Ont., consists of two buildings, A and B, connected by a one-storey cor- ridor. Constructed circa 2010, Build- ing A is a four-storey steel-framed structure with a one-storey garage on the southeast elevation (Figures 3 and 4). The floors and roof slabs are supported by steel beams con- nected to steel columns anchored to cast-in-place footings. Building A has three roof sections: the main roof (A-1), the garage roof (A-2) and the elevator pit room (A-3), as shown in Figure 5. Mechanical equipment on the west side of roof A-1 sits within an open-air screen enclosure. The ap- proximate area of roof A-1 is 645 m2 (6,943 ft.2). The main roof structure of Roof A-1 is a 250-mm (10-in.) thick hol- low-core slab. On top of the slab is a concrete topping that measures 230 mm (nine in.) at the perimeter, tapering to 50 mm (two in.) at the centre to facilitate drainage. The ex- isting roof assembly is a conventional system that includes a self-adhered vapour barrier, 125 mm (five in.) of EPS insulation adhered in place and a 12.7-mm (1/2-in.) fibre board ad- hered in place. The system is capped with a single-ply fully adhered TPO membrane, as depicted in Figure 6. Roof A-1 does not have over- flow scuppers. The existing parapet height is 400 mm (16 in.). Building A has seven drains. CVC Head Office Figure 5: Building A – existing roof plan. Figure 6: Existing A-1 roof assembly.
View this content as a flipbook by clicking here.