18 l ROOFINGBC l SUMMER 2026 TECHNICAL Q & A factored wind uplift resistance to the altered specimens and altered proce- dures used for that attribution shall be documented in an appendix attached to the test report. Refer Annex 1 and 2 for examples. Q7: HOW ARE TEST LABS VERIFIED TO ENSURE UNIFORMITY AND CONSISTENCY AMONG LABORA- TORIES WHEN PERFORMING CSA A123.21 TEST? Several North American labs are claiming that CSA A123.21 tests can be performed. In order to create uniformity and consistency for the interpolation of the standard, SIGDERS created guide- lines for the calibration requirements. This process can be done in accor- dance to the, ISO/IEC 17025; General Requirements for the Competence of Testing and Calibration Laboratories. To ascertain the test accuracy and to maintain the level of confidence via statistical varia- tion, there are two requirements, namely, accuracy of the simulated pressure and ability to maintain the gust dura- tion requirements should be compared and validated. References ANSI/SPRI BPT-1 2021, Test Standard for Comparative Pull-through Strengths of Insulation Fastening Systems and Substrate Board Material Used with Low Slope Roofing Systems. Waltham, MA: American National Standards Institute (ANSI) and the Single Ply Roofing Industry (SPRI). ANSI/SPRI FX-1 2021, Standard Field Test Procedure for Determining the Withdrawal Resistance of Roofing Fasteners. Waltham, MA: American National Standards Institute (ANSI) and the Single Ply Roofing Industry (SPRI). ANSI/SPRI IA-1 2021, Standard Field Test Procedure for Verifying the Suitability of Roof Substrates and Adhesives. Waltham, MA: American National Standards Institute (ANSI) and the Single Ply Roofing Industry (SPRI). ANSI/SPRI MPO-1 2023, Test Standard for Comparative Pull-Over Strengths of Membrane Fastening Systems and Waterproofing Membrane Materials Used with Low Slope Roofing Systems. Waltham, MA: American National Standards Institute (ANSI) and the Single Ply Roofing Industry (SPRI). ASTM D8271-21, Standard Test Method for the Direct Measurement of Surface Profile of Prepared Concrete. ASTM F2659-23, Standard Guide for Preliminary Evaluation of Comparative Moisture Condition of Concrete, Gypsum Cement and Other Floor Slabs and Screeds Using a Non-Destructive Electronic Moisture Meter. Baskaran, A. 2024. Three Decades of scientific advancement to the North American Roofing Community. The IIBEC International Convention and Trade Show, March 8-11, 2024, p. 114-125. Canadian Standards Association. (2026). CAS A123.21:26, Standard test method for the dynamic wind uplift resistance of membrane- roofing systems. K.P. Ko and B. A. Baskaran, 2025. “Application of Concrete as Decking Component for Commercial Building with Adhesive Applied Membrane Roofing System.” Ko and Baskaran, 2024. “How to calibrate a wind test table in accordance to the CSA A123.21-2020, Standard test method for the dynamic wind uplift resistance of membrane roofing systems – Edition 2: Test pressure = 240psf.” FIGURE 3: EXAMPLE OF COMPONENT ARRANGEMENT AND TEST SPECIMEN REQUIREMENT FOR PARS AND AARS. Acknowledgement The presented research is being carried out for a consortium - Special Interest Group for Dynamic Evaluation of Roofing Systems (SIGDERS). SIGDERS was formed from a group of partners who were interested in roofing design. These partners included: Atlas Roofing Corporation, Canadian Roofing Contractors’ Association, Carlisle SynTec Systems, Duro-Last® Roofing, Element Materials Technology, Elevate, EXP Inc., GAF, International Institute of Building Enclosure Consultants, IKO Industries Ltd., Johns Manville Inc., Polyglass, Roofing Contractors Association of British Columbia, ROCKWOOL, Sika Canada Inc., Soprema Canada Inc., Tremco Inc. and Trufast Corporation.
View this content as a flipbook by clicking here.